For an Indian household, estimate the extra units a fan uses before applying the relevant DISCOM tariff. One unit is one kWh. A seasonal schedule avoids treating a fan used for six months as a year-round load. Enter the electrical input at the speed you actually use; a label rating is not a measurement of every operating condition.
Formula
Energy in kWh = power in kW × hours of operation. A weekly schedule is multiplied by 365 ÷ 7; a monthly schedule uses days × 12, capped at 365. Cost = energy × price per kWh. With power and hours entered, the yearly schedule uses your exact number of operating days, without extrapolating the season to a full year.
Worked example
Ceiling-fan use across a cooling season
Hypothetical example, not a tested fan or a current Indian tariff: a 60 W ceiling fan running ten hours on 180 days uses 0.06 × 10 × 180 = 108 units per year. Choose Year and 180 days. At an assumed ₹8 per additional unit, the energy cost is ₹864 for the year, averaging ₹72 per calendar month. In a 30-day month of daily use, it consumes 18 units and costs ₹144 at that same assumed rate.
What the result means
If all 108 additional units face the same rate, multiplying by ₹8 is sufficient. If they cross a slab boundary, split the extra units by slab and sum their costs. For example, 10 extra units at an assumed ₹6 and eight at ₹8 cost ₹124, not 18 × ₹8 = ₹144. This is only an arithmetic illustration; thresholds, subsidies and billing rules depend on your DISCOM and category.
Electricity price · India
Electricity duty, fuel or power purchase adjustments, fixed charges and subsidies depend on the applicable state and DISCOM rules. No national tax percentage or subsidy is assumed. Slab thresholds, sanctioned-load charges and time-of-day tariffs are not automatically modelled.
Assumptions and limits
For a different fan, compare the same airflow requirement, speed and operating hours. Reducing input from 60 W to an assumed 35 W at the same schedule saves 45 units, or ₹360 at ₹8 per unit; it does not prove equivalent airflow. Use the appropriate BEE label and product data, and confirm your tariff's additional-unit rate. Fixed charges, subsidy thresholds and inverter losses are not automatically included in this calculator. BEE and bill-guidance sources are linked below.
Questions answered
Should I enter the appliance’s maximum power?
Measured average power is preferable when the appliance cycles or changes its output.
Does the cost include the whole electricity bill?
No. It estimates the variable energy charge at your chosen rate.
Data sources
- Bureau of Energy Efficiency: Star labelled appliances
- BEE: Appliance label and efficiency questions
- Delhi Electricity Regulatory Commission: Consumer bill guidance
- Ministry of New and Renewable Energy: Rooftop solar
Last reviewed: 2026-09-28